It is suitable for the cultivation of bacteria and microorganisms, used for breeding, fermentation, microbial cultivation, various constant temperature tests, environmental tests, material denaturation tests, and storage of culture media, serum, drugs, etc. It can be widely used in sterility tests such as drugs, textiles, and food processing, and is widely used in research and application fields such as medical and health care, biopharmaceuticals, agricultural research, and environmental protection.
Product Features
v The surface of the box is plated with plastic at high temperature, and the inside of the box is made of 304 stainless steel liner
v Intelligent PID temperature control, accurate temperature control, timing, upper limit deviation alarm, power failure protection and other functions
v Optional 99-segment programmable LCD controller
v Convenient panel control operation, user regulation, easy to use
v Using new silicone rubber sealing strip, long-term high temperature operation
v Independent temperature limit alarm function, automatic power off when the temperature exceeds the limit, safe experiment and avoid accidents
v Standard RS-485 interface is optional, which is convenient for the computer to manage, monitor and print data of multiple devices.
v The shell is made of double-layer cold-rolled plate, which is treated with corrosion-resistant powder baking paint. Arc-shaped inner jaw design, stainless steel acid-resistant material, easy to clean and maintain. Attached with a stainless steel shelf, it is stable and convenient to extract samples, and the double-layer vacuum tempered glass observation window can clearly observe the situation in the chamber, which is simple, beautiful and safer
Technical data sheet
Model |
DHP-050 or DHP-050 H* |
DHP-080 or DHP-080* |
DHP-150 or DHP-150 H* |
DHP-220 or DHP-220* |
DHP-450 or DHP-450 H* |
DHP-640 or DHP-640 H* |
DHP-800 or DHP-800 H* |
||
Power supply |
AC220V 50HZ,Adjustments can be made according to the power requirements of the customer's country . |
||||||||
Volume |
50L |
80L |
150L |
220L |
450L |
640L |
800L |
||
Temperature control range |
RT+5℃-80℃ |
||||||||
Temperature resolution* |
0.1℃ |
||||||||
Temperature uniformity* |
≤0.5℃ |
||||||||
Temperature fluctuation* |
±0.5℃ |
||||||||
Input power |
1000W |
1500W |
2000W |
2450W |
3500W |
4500W |
5300W |
||
Working Temperature |
5-35℃ |
|
|
||||||
Continuous work time |
Not less than 9999 hours |
|
|
||||||
Inner liner size (mm)W*D*H |
350*350*420 |
450*400*450 |
550*500*550 |
550*500*820 |
720*700*900 |
800*800*1000 |
560*1000*1600 |
||
Overall dimensions (mm)W*D*H |
700*600*510 |
730*610*600 |
650*720*910 |
640*720*1110 |
900*1120*1220 |
1000*1290*1220 |
760*1140*2020 |
||
Load carrier (standard configuration) |
2 pieces |
3 pieces |
|||||||
Timing range |
1-9999min |
! H type is a 99 segment programming type
*Temperature uniformity refers to the difference between the maximum value and the minimum value of the average measured temperature at each Test point in the working space of the temperature test equipment within the specified time after the temperature test equipment is stabilized.
*Temperature resolution reflects the sensitivity of a device to temperature. The smaller the temperature resolution, the more obvious the device's perception of temperature changes.
*Temperature fluctuation refers to the difference between the maximum and minimum measured values at any point in the working space of the temperature testing equipment during a specified time interval under stable conditions.